Extract Fans

Extract Fans

SA Extractor Fan Range Bathroom

SA is our wall/ceiling extractor fan perfect for any bathroom, utility or Kitchen, each unit has a back draught shutter attached to stop any unwated drafts from entering from outside.

IP Rating: IP24


Types/Spigot Size

SA100 - 100mm (4")
SA125 - 120mm (5")
SA150 - 150mm (6")

Standard Model (S) - Turns on and off, Live and Neutral needed

Pull Cord (P) - Turns On and Off via the Pull Cord attached to fan, Perm LIve and Neutral Needed

Timer Model (T) - When switched off will run on for the time set

Humidity Model (H) - Turn on and off with Humidity if Switched Live is added fan will also turn on and off with switch. 



Wattage
100 - 14w
125 - 16w
150 - 16w
Air Flow (Free Air)
100 - 97 m3/hr
125 - 183 m3/hr
150 - 290 m3/hr
Sound Level dBA (3m)
100 - 35
125 - 36
150 - 38

Model: STY (Wall/Ceiling Extractor Fan)

STY is our wall/ceiling extractor fan perfect for any bathroom, utility or Kitchen, each unit has a back draught shutter attached to stop any unwated drafts from entering from outside.

IP Rating: IP24


Types/Spigot Size

STY100 - 100mm (4")
STY125 - 120mm (5")
STY150 - 150mm (6")

Standard Model (S) - Turns on and off, Live and Neutral needed

Timer Model (T) - When switched off will run on for the time set

Humidity Model (H) - Turn on and off with Humidity if Switched Live is added fan will also turn on and off with switch. 

Humidity can be wired to just work with humidity if needed



Wattage
100 - 14w
125 - 16w
150 - 16w
Air Flow (Free Air)
100 - 100 m3/hr
125 - 183 m3/hr
150 - 290 m3/hr
Sound Level dBA (3m)
100 - 32
125 - 36
150 - 38

Model: SFP (Plate Fan)
The SFP range is a Commercial Plate Axial Fan perfect for Kitchens, Warehouses, Sports halls, and large areas where high extract rates are needed a low pressure
The SFP Comes in various sizes ranging from 230mm to 480mm

Types/Spigot Size

SFP200 - 230mm
SFP250 - 280mm
SFP300 - 330mm
SFP350 - 380mm
SFP400 - 430mm
SFP450 - 480mm


Pole

SFP200 - 2 Pole

SFP250 - 2 Pole

SFP300 - 2 Pole

SFP350 - 4 Pole

SFP400 - 4 Pole

SFP450 - 4 Pole

 

Wattage

SFP200 - 55w (0.25 A)
SFP250 - 80w (0.36 A)
SFP300 - 145w (0.66 A)
SFP350 - 135w (0.61 A)
SFP400 - 180w (0.82 A)
SFP450 - 250w (1.14 A)
Air Flow (Free Air)
SFP200 - 890 m3/hr
SFP250 - 1100 m3/hr
SFP300 - 2300 m3/hr
SFP350 - 2600 m3/hr
SFP400 - 3830 m3/hr
SFP450 - 4800 m3/hr
Sound Level dBA (3m)
SFP200 - 50
SFP250 - 60
SFP300 - 61
SFP350 - 62
SFP400 - 63
SFP450 - 64
Sold Out

Main features:

  • ABS plastic
  • ball bearings
  • IPX4
  • maximum operating temperature 40°C
  • 1 years warranty

SD-series roof fans are designed for ventilating utility buildings, as well as warehouses with a low level of air pollution.

Fans designed for vertical operation are adapted for installation on roofs with a maximum pitch of 15°.

They have a much-higher compression than traditional fans, so they can work with central exhaust-ventilation systems.

Thanks to the use of 3-speed motors, it is possible to adjust the fan’s parameters to the user’s needs, depending on the connection method.

Model: SWQ (IPX5 Silent Wall/Ceiling Extractor Fan)

SWQ is our wall/ceiling extractor fan perfect for any bathroom, utility or Kitchen, each unit has a back draught shutter attached to stop any unwated drafts from entering from outside.

IP Rating: IPX5

Types/Spigot Size

SWQ100 - 100mm (4")

Models - Timer (T)

Wiring Diagram 


Wattage
100 - 8.4w
Air Flow (Free Air)
100 - 90 m3/hr
Sound Level dBA (3m)
100 - 25
SDISC Extractor Fan

SDISC is our wall/ceiling extractor fan perfect for any bathroom, utility or Kitchen, each unit has a back draught shutter attached to stop any unwated drafts from entering from outside.

It comes with 4 coloured rings - White, Red, Green, Yellow & Blue 

IP Rating: IPX4


Types/Spigot Size

SDISC100 - 100mm (4")


Standard Model (S) - Turns on and off, Live and Neutral needed

Timer Model (T) - When switched off will run on for the time set

Humidity Model (H) - Turn on and off with Humidity if Switched Live is added fan will also turn on and off with switch. 

Wiring diagram 


Wattage
100 - 17w
Air Flow (Free Air)
100 - 105 m3/hr
Sound Level dBA (3m)
100 - 35
Model: SNI (Brushed Extractor Fan)

The SNI range is designed to complment stylish bathrooms, with an unobtrusive, sleek design.

IP Rating: IPX4

Types/Spigot Size

SNI100 - 100mm (4")

Models - Timer (T) & Humidistat (H)

Wiring diagram 

Wattage
100 - 13w
Air Flow (Free Air)
100 - 88 m3/h

Sound Level dBA (3m)
100 - 37
PA
38


Model: SNB (White Extractor Fan)

The SNB range is designed to complment stylish bathrooms, with an unobtrusive, sleek design.

IP Rating: IPX4

Types/Spigot Size

SNB100 - 100mm (4")

Models - Timer (T) & Humidistat (H)

Wiring diagram 

Wattage
100 - 13w
Air Flow (Free Air)
100 - 88 m3/h

Sound Level dBA (3m)
100 - 37
PA
38


Model: SCT (Continuous dMEV)

Swiftair 4"/5” Axial Continuous Running Fan SCT

 

100mm / 125mm continuous running panel axial fan for bathrooms and kitchens.

Discreet styling with flat facia reducing the impact the fan has on interior design.

Suitable for wall or panel mounting using the appropriate fixing kit.

Designed to comply with Building Regulations for whole house system ventilation, this sleek fan can be used in a wet room under System 3 of Building Regulations Approved Document F.

This attractive fan is also very energy efficient.

 

Why choose continuous running fans?

Continuous running fans, like the Continuous range, have been designed to meet the requirements of the Building Regulations for bathrooms, kitchens, utility rooms and toilets (other models available).

The fan is designed to run all of the time, keeping homes fresh, healthy and free from condensation.

 

What does it do?

The fan is designed to run continuously at a very low rate and boost automatically when required.

The low running rate means it has extremely low noise levels.

 

How will it help?

This fan will help prevent the build up of moisture in the home by removing steam and odours.

This will help reduce the risk of black mould forming on walls and behind cupboards.


220-240 V/AC. 50Hz single phase powering a low energy motor.

These fans are double insulated and do not require an earth.

All wiring must comply with current IEE regulations.

 

Models - Timer (T) & Humidistat (H)

Timer (PL, SL & PN)
The fans equipped with a timer (T – time delay) have the possibility of manual shift. Shift the gear up can be done by means of a switch being an element of the building’s electrical installation. The fan may be connected like the basic version (with terminal block) according to two – above mentioned – connection methods. The fan automatically switches to a lower gear 30 minutes after restoring the switch to its original position.


Humidity Only (PL & PN) or Humidity with Timer (PL, SL & PN)

In fans with a humidity sensor (H), the speed is regulated by the controller (regardless of how the unit is connected).
- The fan automatically switches to the second gear if the humidity level exceeds 70%
- The fan automatically switches to the first gear after 15 minutes when the humidity level drops below 70%
- If the humidity level does not exceed 70%, the speed can be increased after turning on a separate switch or the second key on of the double switch (depending on the connection option). The fan will automatically shift to a lower gear 15 minutes after restoring the switch or the second switch to its original position.

 

IP Rating

IPX4


Types/Spigot Size

SCT100 - 100mm (4")
SCR125 - 120mm (5")

Models - Timer (T) & Humidistat (H)

Wiring diagram 

Wattage
100 - 4/6w
125 - 6/8w

Air Flow (Free Air)
100 - 42/70 m3/h
125 - 55/100 m3/h
PA
100 - 11/15
125 - 6/12
Sound Level dB(A)
100 - 26/32
125 - 24/32

Model: SAS (Automatic Shutter Extractor Fan)

A distinctive feature of the SAS fan is the automatic shutters (Please allow 40 secounds to open and fully close).

This design is necessary to combat reverse traction and is indispensable for rooms where regular, but not constant ventilation is needed.

SAS is also has other options: timer & humidity sensor. 

This will help the unit with changes within the room and respond.

IP Rating: IP24



Types/Spigot Size

SAS100A - 100mm (4")
SAS125A - 120mm (5")
SAS150A - 150mm (6")

Standard Model (S) - Turns on and off, Live and Neutral needed

Timer Model (T) - When switched off will run on for the time set

Humidity Model (H) - Turn on and off with Humidity if Switched Live is added fan will also turn on and off with switch. 

Wiring diagram 


Wattage
100 - 11w
125 - 15w
150 - 29w
Air Flow (Free Air)
100 - 85 m3/hr
125 - 130 m3/hr
150 - 230 m3/hr
Sound Level dBA (3m)
100 - 39
125 - 42
150 - 46
Model: SRD (Round Extractor Fan)
For constant or periodic exhaust ventilation of bathrooms, kitchens and other domestic compartments.

Case and impeller are made from the high-quality ABS-plastic, resistant to ultraviolet.

The motor is equipped with overheating protection.

Fixing to the mounting place is carried out by means of screws.

Types/Spigot Size

SRD100 - 100mm (4")
SRD125 - 125mm (5")
SRD150 - 150mm (6")

Models - Standard (S) & Timer (T)

Wiring diagram 


Wattage
SRD100 - 14w
SRD125 - 18w
SRD150 - 22w
Air Flow (Free Air)
SRD100 - 107 m3/hr
SRD125 - 190 m3/hr
SRD150 - 270 m3/hr
Sound Level dBA (3m)
SRD100 - 35
SRD125 - 36
SRD150 - 38

Login